Created on 12/15/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
FPCH
Electro-proportional flow control valve - normally open
SERIES 1 / CAPACITY: 28 L/min. / CAVITY: T-13A
This valve is a normally-open, electro-proportional throttle. The valve is spring biased open. Energizing the coil
generates an closing force on the spool proportional to the command current and this force is countered by the
spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the
current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional
flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with no
command in the 2 to 1 direction is possible without a compensator under all conditions.
TECHNICAL DATA
Maximum Valve Leakage at 110 SUS (24 cSt) 100 cc/min.@210 bar
Manual Override Force Requirement 33 N/100 bar @ Port 1
Manual Override Stroke 2,5 mm
Seal kit - Cartridge Buna: 990-413-007
Seal kit - Cartridge Polyurethane: 990-413-002
Seal kit - Cartridge Viton: 990-413-006
(X)CONTROL
X No Manual Override
D Twist/Lock (Dual) Manual Override
E Twist (Extended) Manual Override
L Twist/Lock (Detent) Manual Override
M Manual Override
T Twist (Momentary) Manual Override
(C)FLOW RATE
C .25 - 7 gpm (1 - 28 L/min.)
A .1 - 1.5 gpm (0,4 - 6 L/min.)
B .15 - 3.5 gpm (0,6 - 14 L/min.)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
COIL *
No coil
212 DIN 43650 3 pin (Hirschman), 12 VDC
224 DIN 43650 3 pin (Hirschman), 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
FPCH
TECHNICAL FEATURES
Available in either a normally open or normally closed configuration with three different capacity ranges.
Capable of operating with pressures up to 5000 psi.
Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
NOTES
Model Code Example: FPCHXCNCONFIGURATION OPTIONS
Created on 12/15/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
Low leakage levels in the closed position.
Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
This cartridge has several manual override choices, including no manual override. See Option Configuration.
For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control
assemblies have a mechanical life expectancy of approximately 7,000 cycles.
The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED ACCESSORIES
773-812 12 VDC weatherized coil with Metri-Pack, Series 150-2M connector
773-814 14 VDC weatherized coil with Metri-Pack, Series 150-2M connector
773-824 24 VDC weatherized coil with Metri-Pack, Series 150-2M connector
773-828 28 VDC weatherized coil with Metri-Pack, Series 150-2M connector
773-836 36 VDC weatherized coil with Metri-Pack, Series 150-2M connector
991-056 T-13A and T-31A cavities, weatherized coil seal kit
991-225 Momentary/twist operation, manual override control kit, T control
991-226 Detent/lock operation, manual override control kit, L control
991-227 Dual twist/lock operation, manual override control kit, D control
991-238 Momentary/twist operation, extended resolution, manual override control kit, E control
991-240 Red momentary/twist operation, manual override control kit, T control
991-241 Red detent/lock operation, manual override control kit, L control
991-242 Red dual twist/lock operation, manual override control kit, D control
991-243 Red momentary/twist operation, extended resolution, manual override control kit, E control